EZFluence

Automated 3D planning in one click

Overview

3D planning, automated

EZFluence by RADformation is an FDA 510(k) cleared, automated 3D planning software. EZFluence generates optimal fluence files and field-in-field plans that import directly into Varian Eclipse TPS and can be accessed through the Eclipse Toolbar.

The ability to automate the 3D planning process using Field-in-Field or E-comp methods with single or mixed energies for multiple sites is now a reality. Addition of Skin Flash to plans can be a tedious and the subjective process which can be automated with EZFluence with the guarantee of consistent high-quality outcomes.

EZFluence works with all types of Beam arrangements, it preserves blocking, automatically produces a PTV Eval structure and produces several plans within seconds which all meet the acceptance criteria set by the user. The users can switch between the generated plans and review the dose distribution, make changes to the MLC arrangement and see the updated dose distribution, edit the fluence using dose painting, choose the number of segments and minimum MUs required for each segment for field-in-field plans and send the plan back to ECLIPSE TPS for final dose calculation using ECLIPSE dose calc algorithm all within minutes.

Any site, any configuration

EZFluence works for any beam arrangement and any treatment site from head to toe. It standardises field-in-field planning regardless of the user while maintaining or improving plan quality compared to manual techniques.

IMRT/VMAT to 3D plan conversion

Billing justification plans are no longer a hassle or stress to clinical resources; our automatic 3D converter tool takes the pain out of the justification process. Any IMRT or VMAT plan can be easily converted to a 3D plan in a matter of seconds.

Breast Planning

EZFluence follows ASTRO’s guidelines for whole breast treatment. Automate field-in-field and e-comp planning. Optimize coverage while minimizing the maximum dose and V105%.

  • Preserve MLC blocking
  • Generate fluence for the flash region
  • Use on single or mixed energy plans
  • Auto-contour the PTV Eval

 

3 & 4 field breast planning

EZFluence automatically sets the SCLAV and PAB field weighting. Control the match line in monoisocentric plans with EZFluence by increasing coverage and minimizing hot spots.

 

Simultaneous integrated boost

For clinics following RTOG 1005, EZFluence allows the user to boost coverage to lumpectomy volumes. Instantly plan integrated boost plans.

Lung Planning

Generate homogenous dose distributions in seconds for 3D lung plans. EZFluence works for any beam arrangement including non-coplanar beams. Say goodbye to wedges and time-consuming field-in-field planning.

Pelvis planning

Still using wedges for 3-field rectum plans? EZFluence can automatically generate the fluence or field-in-field segments for the lateral beams. Compatible with single energy or mixed energies.

Whole-brain field-in-field

EZFluence automatically generates custom segments for patient’s plans. The user sets how many segments desired for each field.

Extremities & more

EZFluence supports any 3D treatment site.

  • Larynx
  • Shoulder
  • Hips
  • Ribs
  • APPA Spine